The RowCool R Series utilizes a direct expansion (DX) cooling method, which involves the use of a refrigerant to absorb heat directly from the air within the data center.
This highly efficient cooling process eliminates the need for a secondary fluid loop, making it a cost-effective and space-saving solution. The system's capacity ranges from 30 to 45 kW, providing scalable cooling capabilities to meet the varying needs of different data center sizes.
One of the key features of the RowCool R Series is its modular design. The system is composed of individual cooling units, each capable of independent operation. This modularity not only enhances the system's flexibility but also simplifies maintenance and allows for easy replacement or addition of cooling units without disrupting the entire cooling infrastructure.
To ensure precise temperature control, the RowCool R Series incorporates intelligent controls. These controls continuously monitor temperature and humidity levels within the data center, adjusting cooling output accordingly to maintain the ideal conditions. This not only optimizes cooling efficiency but also helps reduce energy consumption, contributing to a greener and more sustainable data center operation.
The precision cooling system also employs variable speed fans to further enhance its efficiency. The fans can adjust their rotational speed based on real-time cooling requirements, reducing unnecessary energy consumption during periods of lower heat load. As a result, the RowCool R Series can achieve significant energy savings while ensuring consistent and reliable cooling performance.
The system's airflow design is optimized to minimize hotspots and maintain uniform cooling across all IT equipment.
Cold air is directed efficiently to the front of server racks, while hot air is effectively expelled from the rear, preventing the mixing of hot and cold air streams that could compromise cooling effectiveness.
In terms of installation and maintenance, the RowCool R Series is engineered for user convenience. The units are designed for easy access, and the front-facing components are easily replaceable, minimizing downtime during repairs or servicing. Additionally, the cooling system features built-in diagnostics and proactive alerts, facilitating prompt response to potential issues and reducing the risk of critical equipment failures.
The RowCool R Series is also designed with environmental considerations in mind. It uses eco-friendly refrigerants that have low global warming potential (GWP), aligning with the industry's efforts to reduce the overall carbon footprint of data centers.